Sample Type | Fresh capillary whole blood |
---|---|
Enzyme | GOD |
Sample Size | 0.5 μL |
Measurement Time | 5 seconds |
Measurement Range | 20-600 mg/dL |
Hematocrit | 15-65% |
Dimension | 96.9 x 50 x 14.6 mm |
Weight | 50.5 g |
Calibration Method | Auto-coding |
Strip Type | CareSens® N Strip |
---|---|
Memory | 1,000 tests |
Power Source | One 3.0V lithium battery (CR2032) |
Battery Life | 1,000 tests |
Operating Temperature | 42.8-111.2°F (6-44°C) |
Strip Storage Temperature | 34-86°F (1-30°C) |
Operating Humidity | 10-90% |
Strip Shelf Life | 24 months from manufacturing date |
Communication | USB, Bluetooth® |
Sample Type | Fresh capillary whole blood |
---|---|
Enzyme | GOD |
Sample Size | 0.5 μL |
Measurement Time | 5 seconds |
Measurement Range | 20-600 mg/dL (1.1-33.3 mmol/L) |
Hematocrit | 20-60% |
Dimension | 93 x 47 x 15 mm |
Weight | 51.5 g |
Calibration Method | Auto-coding |
Strip Type | CareSens® N Strip |
---|---|
Memory | 250 tests |
Power Source | Two 3.0V lithium batteries (CR2032) |
Battery Life | 1,000 tests |
Operating Temperature | 50-104°F (10-40°C) |
Strip Storage Temperature | 34-86°F (1-30°C) |
Operating Humidity | 10-90% |
Strip Shelf Life | 24 months from manufacturing date |
Communication | USB |
Sample Type | Fresh capillary whole blood |
---|---|
Enzyme | GOD |
Sample Size | 0.5 μL |
Measurement Time | 5 seconds |
Measurement Range | 20-600 mg/dL (1.1-33.3 mmol/L) |
Hematocrit | 15-65% |
Dimension | 108.4 x 55.8 x 15 mm |
Weight | 65.5 g |
Calibration Method | Auto-coding |
Strip Type | CareSens® N Strip |
---|---|
Memory | 1,000 test results |
Power Source | Two 3.0V lithium batteries (CR2032) |
Battery Life | 1,000 tests |
Operating Temperature | 42.8-111.2°F (6-44°C) |
Strip Storage Temperature | 34-86°F (1-30°C) |
Operating Humidity | 10-90% |
Strip Shelf Life | 24 months from manufacturing date |
Communication | USB, Bluetooth® |
Sample Type | Fresh capillary whole blood |
---|---|
Enzyme | GOD |
Sample Size | 0.5 μL |
Measurement Time | 6 seconds |
Measurement Range | 40-600 mg/dL |
Hematocrit | 20-60% |
Dimension | 95 x 49 x 17.5 mm |
Weight | 50.5 g |
Calibration Method | Auto-coding |
Strip Type | CareSens® S Strip |
---|---|
Memory | 1,000 test |
Power Source | One 3.0V lithium battery (CR2032) |
Battery Life | 1,000 tests |
Operating Temperature | 50-104°F (10-40°C) |
Strip Storage Temperature | 34-86°F (1-30°C) |
Operating Humidity | 10-90% |
Strip Shelf Life | 24 months from manufacturing date |
Communication | USB, Bluetooth® |
Sample Type | Fresh capillary & venous whole blood |
---|---|
Enzyme | HBDH |
Sample Size | 0.5 μL |
Measurement Time | 8 seconds |
Measurement Range | 0.1-8.0 mmol/L |
Hematocrit | 20-55% |
Dimension | 106 x 58 x 17 mm |
Weight | 71.8 g |
Calibration Method | Auto-coding |
Strip Type | KetoSens® Strip |
---|---|
Memory | 1,000 test results |
Power Source | Two 3.0V lithium batteries (CR2032) |
Battery Life | 3,000 tests |
Operating Temperature | 50-104°F (10-40°C) |
Strip Storage Temperature | 39-86°F (4-30°C) |
Operating Humidity | 10-90% |
Strip Shelf Life | 18 months from manufacturing date |
Communication | USB |
Sample Type | Fresh capillary & whole blood |
---|---|
Enzyme | HBDH |
Sample Size | 0.5 μL |
Measurement Time | 8 seconds |
Measurement Range | 0.1-8.0 mmol/L |
Hematocrit | 20-55% |
Dimension | 106 x 58 x 17 mm |
Weight | 71.8 g |
Calibration Method | Auto-coding |
Strip Type | KetoSens® Strip |
---|---|
Memory | 1,000 test results |
Power Source | Two 3.0V lithium batteries (CR2032) |
Battery Life | 3,000 tests |
Operating Temperature | 50-104°F (10-40°C) |
Strip Storage Temperature | 39-86°F (4-30°C) |
Operating Humidity | 10-90% |
Strip Shelf Life | 18 months from manufacturing date |
Communication | USB, Bluetooth® |
Sample Type | Fresh capillary & whole blood |
---|---|
Enzyme | GDH-FAD |
Sample Size | 0.4 μL |
Measurement Time | 5 seconds |
Measurement Range | 20-600 mg/dL |
Hematocrit | 15-65% |
Dimension | 92 x 52 x 21 mm |
Weight | 55 g |
Calibration Method | Auto-coding |
Strip Type | VetMate® Strip |
---|---|
Memory | 500 test results |
Power Source | Two 3.0V lithium batteries (CR2032) |
Battery Life | 3,000 tests |
Operating Temperature | 41-113°F (5-45°C) |
Strip Storage Temperature | 34-86°F (1-30°C) |
Operating Humidity | 10-90% |
Strip Shelf Life | 24 months from manufacturing date |
Communication | USB |